Giraffe OmniBed Field Replaceable Unit (FRU), Model Numbers 6600-1056-400 and 6600-1461-500
GE HealthCare has become aware of a potential issue involving the canopy soffit beneath the control panel end of the device. Under certain conditions, for example, impact during transport, one or more of the fasteners that secure the soffit can disengage. If this occurs, a fastener could fall into the patient compartment. In rare circumstances, if multiple fasteners disengage, the canopy soffit can become loose or detach. These conditions could potentially result in patient injury.
|
FDA
Z-2477-2026
|
Medical Device | High |
Jun 24, 2026
Recall: May 1, 2026
|
Details |
|
MEDLINE Urethral Catheterization Tray, Red Rubber Latex, Medline Product Number/SKU (REF), French sizes: 1. DYNC1816, 15 Fr; 2. DYND10350, 15 Fr.
During an internal review, Medline identified representative samples did not meet applicable performance specifications. Identified issues include irregularities in catheter surface finish, instances where the catheter connector detached prematurely from the catheter funnel, and limited cases where the catheter outer diameter did not meet specification.
|
FDA
Z-2480-2026
|
Medical Device | High |
Jun 24, 2026
Recall: May 4, 2026
|
Details |
|
Description/REF: RA CATH KIT: 20 GA X 1 3/4 IN/TJ-04020-1; RA CATH KIT: 20 GA X 1 1/2IN/NA-04220-S1A; ARTERIAL LINE KIT/AK-04510-S; ARTERIAL CATH KIT: 18 GA X 6IN (16 CM)/ASK-04018-HUMC; ARTERIAL LINE KIT: 18 GA X 6 IN (16 CM)/ASK-04018-OH1; RA CATH KIT: 20 GA X 1 3/4IN (4.45 CM)/ASK-04020-BID; RA CATH KIT: 20 GA X 1-3/4IN/ASK-04020-MAR; ARTERIAL LINE KIT: 20 GA X 5 IN/ASK-04020-PM4; RA CATH KIT: 20 GA X 1 1/2IN (3.81 CM)/ASK-04120-HF3; RA CATH SET: 20 GA X 2 1/2 IN (6.35 CM)/ASK-04120-UR; ARTERIAL CATH KIT: 20 GA X 3 1/16 IN/ASK-04125-MGH; ARTERIAL CATH KIT: 20 GA X 5 IN/ASK-04500-HFH4; ARTER
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
|
FDA
Z-2368-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 21, 2026
|
Details |
|
Medline convenience kits: C SECTION CDS985505G C SECTION PACK DYNJ68260D C-SECTION DYNJ905094B C-SECTION RECOVERY #2 CDS820091P
Kits contain recalled lot of Ferndale Laboratories MASTISOL Liquid Adhesive. Butyrate tubing may crack during actuation and render product unusable for application.
|
FDA
Z-2446-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 27, 2026
|
Details |
|
MEDLINE Urethral Catheterization Tray and Bag, Red Rubber Latex, 15 Fr, Medline Product Number/SKU (REF) DYND18350
During an internal review, Medline identified representative samples did not meet applicable performance specifications. Identified issues include irregularities in catheter surface finish, instances where the catheter connector detached prematurely from the catheter funnel, and limited cases where the catheter outer diameter did not meet specification.
|
FDA
Z-2482-2026
|
Medical Device | High |
Jun 24, 2026
Recall: May 4, 2026
|
Details |
|
Product Name: STAAR ICL Calculation Software Software Version: Version 8.00 Product Description: The STAAR ICL Calculation Software is designed as an aide in the calculation of the size and diopter power (with residual refraction) for physician selection of the lens. For toric ICLs, an Implantation Orientation Diagram (IOD) is also produced to provide the physician with pictorial representation of the axis of rotation and alignment. Note: The STAAR ICL Calculation Software resides on STAAR Surgical's e-commerce website in STAAR ICL planning support (Stella), as referenced in the attached recal
Due to a software coding issues for calculating the implant orientation diagram printout for the implantation for toric implantable collamer lenses.
|
FDA
Z-2509-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 20, 2026
|
Details |
|
Description/REF: CVC KIT: 16 GA X 8IN/AK-04210, CVC KIT: 1-L 16 GA X 8IN (20 CM)/AK-04300, CVC KIT: 14 GA X 6 IN/CK-04711
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
|
FDA
Z-2396-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 21, 2026
|
Details |
|
TRI TS BASEPLATE SIZE 4. Part Number: 5521-B-400.
Stryker has identified that Triathlon Universal Baseplate Size 3 (lot UZD9IB), is contained in packaging labeled as Triathlon Universal Baseplate Size 4 (lot TYX7OB), and Triathlon Universal Baseplate Size 4 (lot TYX7OB), is contained in packaging labeled as Triathlon Universal Baseplate Size 3, (lot UZD9IB).
|
FDA
Z-2462-2026
|
Medical Device | High |
Jun 24, 2026
Recall: May 19, 2026
|
Details |
|
Medline convenience kits: INPATIENT CENTRAL LN DRSG KIT DYNDC3525 PICC/CVC/MIDLINE DRSG CHG KIT DT13191A PORT A CATH CDS982047S VEIN ABLATION PACK DYNJ62889C
Kits contain recalled lot of Ferndale Laboratories MASTISOL Liquid Adhesive. Butyrate tubing may crack during actuation and render product unusable for application.
|
FDA
Z-2419-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 27, 2026
|
Details |
|
MEDLINE Urethral Catheter, Red Rubber Latex, Medline Product Number/SKU (REF), French sizes: 1. DYND13508 - 08 Fr; 2. DYND13510 - 10 Fr; 3. DYND13512 - 12 Fr; 4. DYND13514 - 14 Fr; 5. DYND13515 - 15 Fr; 6. DYND13516 - 16 Fr; 7. DYND13518 - 18 Fr; 8. DYND13520 - 20 Fr; 9. DYND13522 - 22 Fr; 10. DYND13614 - 14 Fr; 11. DYND13616 - 16 Fr.
During an internal review, Medline identified representative samples did not meet applicable performance specifications. Identified issues include irregularities in catheter surface finish, instances where the catheter connector detached prematurely from the catheter funnel, and limited cases where the catheter outer diameter did not meet specification.
|
FDA
Z-2479-2026
|
Medical Device | High |
Jun 24, 2026
Recall: May 4, 2026
|
Details |
|
Panda Freestanding Warmer, Infant Radiant Warmer Product Identifiers: 2063568-001 Impacted only if service blender M1091607-R was installed during the last Preventative Maintenance.
Blender knob shaft can loosen, which can affect the delivered oxygen concentration. The system can deliver an oxygen concentration that does not match the intended concentration set by the user, potentially resulting in hypoxia or hyperoxia in the patient.
|
FDA
Z-2359-2026
|
Medical Device | High |
Jun 24, 2026
Recall: May 8, 2026
|
Details |
|
Medline convenience kits: BREAST IMAGING DYNJT5893 CHOG PLASTICS SYNJ10306A ENDO BREAST AUGMENTATION PACK DYNJ68023 FACIAL PLASTIC DYNJ909926C JVL - MODULE PLASTIC PK DYNJ84081B KIT MAJOR PLASTICS MOSES DYNJ905362C MEM MAXILLOFACIAL PACK-LF DYNJ0660040R MINOR BREAST PACK DYNJ89023A PLASTIC MAJOR SURGERY DYNJ902510M PLASTIC PACK DYNJ84766 PLASTIC PACK-LF DYNJ0578842M PLASTICS EXTREMITY PACK DYNJ63803C PLASTICS PK - NO SYR DYNJ62433D RR-ASC-RHINOPLASTY PACK-LF DYNJ81772C TRANSGENDER PACK DYNJT7588 WH PLASTIC MAJOR PACK DYNJ89048A
Kits contain recalled lot of Ferndale Laboratories MASTISOL Liquid Adhesive. Butyrate tubing may crack during actuation and render product unusable for application.
|
FDA
Z-2423-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 27, 2026
|
Details |
|
Medline convenience kits: HYSTERECTOMY PACK-LF DYNJ20485L
Kits contain recalled lot of Ferndale Laboratories MASTISOL Liquid Adhesive. Butyrate tubing may crack during actuation and render product unusable for application.
|
FDA
Z-2447-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 27, 2026
|
Details |
|
Description/REF: PSI KIT: 7 FR X 4 IN/ASK-09701-UP; PSI KIT: 8.5 FR X 4 1/8 IN (10 CM)/ASK-09803-OSU5; PSI KIT: 8.5 FR/ASK-09807-UC; PSI KIT: 9 FR X 4 1/8IN (10 CM)/ASK-09903-HH2; PSI KIT: 9 FR X 10 CM/ASK-09903-LMDTG; PSI KIT: 9 FR X 4 1/8 IN (10 CM)/ASK-09903-OSU5; PSI KIT: 9 FR X 10 CM/CDC-09903-1A; MAC KIT: 2L 9 FR DISTAL X 11.5 CM/ASK-11242-KSF2; MAC TWO LUMEN/PSI KIT: 9 FR X 11.5 CM/ASK-11242-KSF1 AGB MAC KIT: 2L 9 FR DISTAL/ASK-21242-MCY1; MULTI LUMEN PSI KIT: 9 FR DISTAL X 4 1/2/ASK-21242-OSU4; MAC KIT: 2-L 9 FR DISTAL X 11.5 CM/ASK-21242-UCD1; 2L MAC KIT: 9 FR DISTAL X 4 IN/ASK-21142-
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
|
FDA
Z-2393-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 21, 2026
|
Details |
|
Medline convenience kits: BIB AV FISTULA PACK DYNJ58304B CARDIAC MINOR SURGICOUNT PACK DYNJ56573B ENDOVASCULAR PACK DYNJ29135N EP DEVICE DYNJ65916B FULL LINE ANEURYSM CDS CDS983672P GEN FEM POP #14-RF DYNJ21877W IMPLANT PACK DYNJ39316D OPEN HEART MRNGSD DYNJ58354F PACEMAKER PACK-LF DYNJ0618174N PACEMAKER SETUP PACK DYNJ35761D PACER / CATH LAB PACK-LF DYNJ0972604A PACER CDS CDS983686I PACER PACK DYNJ52059D PK, EP LAB PACEMAKER DYNJ43663A VENOUS ACCESS PACK DYNJ45640B
Kits contain recalled lot of Ferndale Laboratories MASTISOL Liquid Adhesive. Butyrate tubing may crack during actuation and render product unusable for application.
|
FDA
Z-2444-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 27, 2026
|
Details |
|
FDA
Z-2520-2026
|
Medical Device | High |
Jun 24, 2026
Recall: May 13, 2026
|
Details | |
|
Description/REF: BIOPSY SYSTEM COMPREHENSIVE KIT/ASK-09458-AH, ASK-09458-COC, ASK-09458-EUH, ASK-09458-SD, ASK-09458-VU
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
|
FDA
Z-2365-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 21, 2026
|
Details |
|
Medline convenience kits: ADD-A-CATH ARTERIAL INSERTION ARTNC185 PED SCHOOL AGE PICC DRSG TRAY DYNDC3291
Kits contain recalled lot of Ferndale Laboratories MASTISOL Liquid Adhesive. Butyrate tubing may crack during actuation and render product unusable for application.
|
FDA
Z-2445-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 27, 2026
|
Details |
|
MEDLINE Medical Procedure Kits labeled as: 1) D AND C PACK, Medline Kit Number/SKU DYNJ53973C; 2) PK CUST CV A&B CABRINI CO, Medline Kit Number/SKU DYNJ60583C.
During an internal review, Medline identified representative samples did not meet applicable performance specifications. Identified issues include irregularities in catheter surface finish, instances where the catheter connector detached prematurely from the catheter funnel, and limited cases where the catheter outer diameter did not meet specification.
|
FDA
Z-2504-2026
|
Medical Device | High |
Jun 24, 2026
Recall: May 4, 2026
|
Details |
|
Description/REF: ACCESS TRAY/ASK-04001-SUH-S; ACCESS TRAY/ASK-04001-VM1; STIMUCATH SFTY KIT: 19G CTH, 17Gx4CM NDL/AB-19604-KS; STIMUCATH SFTY KIT: 19G CTH, 17Gx8CM NDL/AB-19608-KS; STIMUCATH SFTY KIT: 20G CTH, 18Gx8CM NDL/AB-20608-KS; STIMUCATH KIT: 19G CATH, 17G x 9CM NDL/AB-05060-PK; FLEXBLOCK ULTRASOUND KIT: 17Gx9CM NS NDL/ASK-19609-VCU; CONTINUOUS NERVE BLOCK KIT/ASK-19600-CC2; CONTINUOUS NERVE BLOCK KIT 19 GA X 60/ASK-19608-CC; CONTINUOUS NERVE BLOCK KIT 19GA X 60CM/ASK-19608-KP; CONTINUOUS NERVE BLOCK KIT 19GA X 60CM/ASK-19608-SHC; FLEXBLOCK KIT:ECHO CATH, 17Gx8CM STM NDL/FB-19608-K; FLE
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
|
FDA
Z-2364-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 21, 2026
|
Details |
|
Mito Red Light, Super Mobile
The near-infrared therapy device contains a lithium-ion battery that may malfunction, causing it to catch fire or burst into flames.
|
FDA
Z-2478-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Feb 12, 2025
|
Details |
|
MEDLINE Medical Procedure Kits labeled as: 1) BR L&D PACK, Medline Kit Number/SKU DYNJ47625B; 2) GYN VAGINAL, Medline Kit Number/SKU DYNJ912219; 3) KIT MAJ VAG SET UP, Medline Kit Number/SKU DYNJ907033B; 4) MINOR VAG PACK, Medline Kit Number/SKU DYNJ68663B; 5) OB DELIVERY PACK, Medline Kit Number/SKU DYNJ14099F; 6) OB DELIVERY PACK, Medline Kit Number/SKU DYNJ14099G; 7) OB PACK, Medline Kit Number/SKU DYNJ03387B; 8) OB PACK, Medline Kit Number/SKU DYNJ03387C; 9) OB PACK, Medline Kit Number/SKU DYNJ53543B; 10) RR-D/E PACK, Medline Kit Number/SKU DYNJ62645D; 11) RR-D/E PACK, Medline Kit Number/S
During an internal review, Medline identified representative samples did not meet applicable performance specifications. Identified issues include irregularities in catheter surface finish, instances where the catheter connector detached prematurely from the catheter funnel, and limited cases where the catheter outer diameter did not meet specification.
|
FDA
Z-2501-2026
|
Medical Device | High |
Jun 24, 2026
Recall: May 4, 2026
|
Details |
|
Description/REF: RA CATH KIT: 20 GA X 1-1/2IN/NA-04220-1A; RA CATH KIT: 20 GA X 1-1/2IN/NA-04220-X1A; ARTERIAL CATHETER KIT: 18 GA X 16 CM/ASK-04018-HCA; ARTERIAL CATHETER KIT: 18 GA X 16 CM/ASK-04018-UPM; RA CATH KIT: 20 GA X 1-3/4IN/ASK-04020-HC; ARTERIAL LINE KIT: 20 GA X 5IN (12 CM)/ASK-04020-HMC; RADIAL ARTERY CATHETER KIT: 20 GA X 30MM/ASK-04020-MMC; RA CATH KIT: 20 GA X 1-1/2IN (3.81 CM)/ASK-04020-SV; ARTERIAL CATH KIT: 20 GA X 5 IN (12 CM)/ASK-04100-AMC-S1; ARTERIAL CATHETER KIT: 20 GA X 12 CM/ASK-04100-NS; RADIAL ARTERY KIT/ASK-04500-AH; RAD ART:20GAX3.81CM / ART LINE:20GAX12CM/ASK-04
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
|
FDA
Z-2397-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 21, 2026
|
Details |
|
MEDLINE Medical Procedure Kits labeled as BASIC GYN, CW LAP GYN, D&C HYSTEROSCOPY, CW LAP GYN, DEACONESS PELVIC LAP PACK, FLOYD LAP GYN, GYN LAP PACK, GYN LAPAROSCOPY, GYN MINOR PACK, etc. (see the recall documents for a full list of affected products)
During an internal review, Medline identified representative samples did not meet applicable performance specifications. Identified issues include irregularities in catheter surface finish, instances where the catheter connector detached prematurely from the catheter funnel, and limited cases where the catheter outer diameter did not meet specification.
|
FDA
Z-2503-2026
|
Medical Device | High |
Jun 24, 2026
Recall: May 4, 2026
|
Details |
|
Description/REF: PACING/PSI KIT: 5 FR 2L/ASK-07155-MGU
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
|
FDA
Z-2383-2026
|
Medical Device | High |
Jun 24, 2026
Recall: Apr 21, 2026
|
Details |
Review FDA device recalls and early alerts for equipment, software, monitors, implants, diagnostic tools and patient-use devices.
Use the device name, company, product code, UDI, model, catalog number, serial number, lot number, software version or implant card details.
Class I recalls are generally the most serious. Read the FDA notice for patient risk, affected devices, correction/removal steps and clinical action.
If the device supports or monitors health, do not stop treatment based only on a search result. Confirm with the official notice and your clinician when needed.
Use each recall result to compare device name, company, product code, model, serial, lot number, UDI and software version. A similar name is not enough; recalls often apply only to specific versions or production ranges.
Check the notice for FDA recall class, patient risk, correction, removal and clinical action. This helps you decide whether the item should be stopped immediately or handled through a normal remedy process.
Review retailer, online marketplace, state, distribution and purchase-date details when they are available. Some recalls apply only to certain stores or channels.
Use the linked official notice for final instructions such as repair, replacement, refund, disposal, software update, stop-use or company contact.
Search the product name or brand, then compare model, serial, lot, code, date, retailer and official recall number details on the detail page.
Stop using the product if the official notice says to do so, keep the label or packaging, and follow the remedy instructions for repair, refund, replacement or disposal.
Recalls can be limited to certain production dates, factories, lots, model numbers, colors, sizes, retailers or distribution areas.
No. This page helps you search public recall data. Use the linked agency or company notice as the final source before taking action.