MEDLINE convenience kits labeled as: 1) C-SECTION, Medline SKU DYNJ910835; 2) C-SECTION, Medline SKU DYNJ910835A; medical convenience kits
Medline Industries, LP is issuing a recall for specific Medline kits containing B. Braun convenience kits that include Bupivacaine Hydrochloride in Dextrose Injection, USP. B. Braun Medical Inc. was notified by their supplier, Spectra Medical Devices, LLC of a product recall from Huons Co, Ltd., the manufacturer of Bupivacaine Hydrochloride in Dextrose Injection, USP. Huons Co, Ltd. has issued a voluntary recall of this product due to quality issues.
|
FDA
Z-2748-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 5, 2026
|
Details |
|
SnapshotGLO Wound Imaging Device, Model KB100, KB100AA.
The software controlling the wound imaging device's battery charging circuit was not designed to recognize and recover a battery that has fully discharged into a low-power "shipping mode." When this occurs, an affected device will not resume charging when reconnected to power and becomes temporarily unusable/ unavailable for wound imaging until corrected.
|
FDA
Z-2775-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 30, 2026
|
Details |
|
Halyard EYE PACK. Model/Catalog Number: LVEY27 Convenience kit.
Incorrect concentration of Betadine solution contained within certain AVID convenience kits.
|
FDA
Z-2763-2026
|
Medical Device | High |
Jul 29, 2026
Recall: May 7, 2026
|
Details |
|
The intended use is to be paired with a weapon for aiming purposes.
Wilcox is notifying all customers who have purchased a product from the BOSS Xe family that a software enhancement to increase safety has been released and all units should be returned to implement this change.
|
FDA
Z-2675-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Apr 6, 2026
|
Details |
|
Medline convenience kits containing Bard¿ Silastic¿ Foley Catheters (French sizes 16, 18, 20) 5cc balloons. KIT ROBOTICS UROLOGY PROSTATE DYKMBNDL116G
Affected kits contain recalled Bard Silastic Foley Catheters. Catheters were recalled by manufacturer due to increased amount of raw material present on the surface of the catheter. Issue may result in the use of urinary catheters that exhibit staining on the catheter surface; raw material present in increased amounts may be harmful.
|
FDA
Z-2787-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 8, 2026
|
Details |
|
MEDLINE ANTERIOR HIP, Medline Kit SKU DYNJ909640G
Medline Industries, LP is issuing a recall for specific Medline kits containing B. Braun convenience kits that include Bupivacaine Hydrochloride in Dextrose Injection, USP. B. Braun Medical Inc. was notified by their supplier, Spectra Medical Devices, LLC of a product recall from Huons Co, Ltd., the manufacturer of Bupivacaine Hydrochloride in Dextrose Injection, USP. Huons Co, Ltd. has issued a voluntary recall of this product due to quality issues.
|
FDA
Z-2747-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 5, 2026
|
Details |
|
P28 PHANTON INTRAMEDULLARY NAIL SYSTEM, Phantom Hindfoot TTC/TC Ball Tipped Guide Rod, SIZE: 0.30 mm, LENGTH: 800 mmm, ITem number P31-955-1800-S; provides stabilization of the hindfoot and ankle.
Paragon 28 received two (2) complaints were received involving breaches in the sterile barrier of the pouch packaging.
|
FDA
Z-2758-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 17, 2026
|
Details |
|
FARASTAR PFA Generator, Product ID M004PFCE61M460; Percutaneous Cardiac Ablation Catheter
Labeling discrepancy: Devices distributed with Instructions For Use (IFU) did not include FARAPOINT PFA catheter information.
|
FDA
Z-2752-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 11, 2026
|
Details |
|
Pipeline Flex Embolization Device with Shield Technology, 3.00 mm x 20 mm 027 REF PED2-300-20
Incorrect labeling - embolization devices labeled as 3.0 mm x 20 mm implants contain 12 mm implants, and devices labeled as 3.0 mm x 12 mm implants contain 20 mm implants.
|
FDA
Z-2774-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 8, 2026
|
Details |
|
Ventriculostomy Kit, REF: 46154
Ventriculostomy devices, used during ventriculostomy procedures to gain access to the ventricular system, may exhibit endotoxin levels that exceed the acceptable limit for devices that come into contact with cerebrospinal fluid; endotoxin exposure can cause an acute inflammatory process.
|
FDA
Z-2768-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 17, 2026
|
Details |
|
Medline medical convenience kits labeled as: 1) TOTAL JOINT PACK Medline Kit SKU DYNJ65065A: 2) EXTREMITY/FOOT PACK Medline Kit SKU DYNJ65066B: 3) ANTERIOR CERVICAL-SMH Medline Kit SKU DYNJ907718B: 4) LAMINECTOMY-SMH Medline Kit SKU DYNJ907732C: 5) KYPHOPLASTY Medline Kit SKU DYNJ907984C: 6) LUMBAR LAMINECTOMY Medline Kit SKU DYNJ907987D: 7) KYPHOPLASTY TRAY Medline Kit SKU DYNJ908413C: 8) CRANIOTOMY Medline Kit SKU DYNJ910626: 9) NEURO SPINE Medline Kit SKU DYNJ910639.
Medline Industries, LP is issuing a recall for specific Medline convenience kits containing BD PurPrep 26 mL which may be contaminated with low levels of Bacillus species.
|
FDA
Z-2791-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 11, 2026
|
Details |
|
Medline convenience kits containing Bard¿ Silastic¿ Foley Catheters (French sizes 16, 18, 20) 5cc balloons. KIT ROBOTICS UROLOGY PROSTATE DYKMBNDL116I
Affected kits contain recalled Bard Silastic Foley Catheters. Catheters were recalled by manufacturer due to increased amount of raw material present on the surface of the catheter. Issue may result in the use of urinary catheters that exhibit staining on the catheter surface; raw material present in increased amounts may be harmful.
|
FDA
Z-2779-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 8, 2026
|
Details |
|
Medline medical convenience kits labeled as: 1) SHOULDER PACK, Medline Kit SKU DYNJ39590O; 2) SHOULDER PACK, Medline Kit SKU DYNJ88566; 3) MAJOR ORTHO KIT, Medline Kit SKU DYNJ911535.
Medline Industries, LP is issuing a recall for specific Medline convenience kits containing BD PurPrep 26 mL which may be contaminated with low levels of Bacillus species.
|
FDA
Z-2789-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 11, 2026
|
Details |
|
Medline convenience kits containing Bard¿ Silastic¿ Foley Catheters (French sizes 16, 18, 20) 5cc balloons. UROLOGY ROBOTIC PROCEDURE PACK DYNJ0945779U
Affected kits contain recalled Bard Silastic Foley Catheters. Catheters were recalled by manufacturer due to increased amount of raw material present on the surface of the catheter. Issue may result in the use of urinary catheters that exhibit staining on the catheter surface; raw material present in increased amounts may be harmful.
|
FDA
Z-2781-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 8, 2026
|
Details |
|
Power F2 Powered Fastening System, Product No. 0567091 Powered fastening system intended for professional use only. Designed to load, unload, and secure a compatible wheeled stretcher inside a ground-based ambulance. Item no. 0567091
Product may experience accelerated roller wear and potential deformation due to interference between the roller assembly and rail. In the worst-case condition, rail mechanism may become lodged during operation and movement of the stretcher along the rail may no longer be possible through either powered or manual operation. May cause delays in transport of patient to healthcare facility.
|
FDA
Z-2760-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 19, 2026
|
Details |
|
FARASTAR Pulsed Field Ablation Generator, Product ID M004PFCE61M401; Percutaneous Cardiac Ablation Catheter
Labeling discrepancy: Devices distributed with Instructions For Use (IFU) did not include FARAPOINT PFA catheter information.
|
FDA
Z-2751-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 11, 2026
|
Details |
|
Medline convenience kits containing Bard¿ Silastic¿ Foley Catheters (French sizes 16, 18, 20) 5cc balloons. ROBOTIC CDS980523M
Affected kits contain recalled Bard Silastic Foley Catheters. Catheters were recalled by manufacturer due to increased amount of raw material present on the surface of the catheter. Issue may result in the use of urinary catheters that exhibit staining on the catheter surface; raw material present in increased amounts may be harmful.
|
FDA
Z-2784-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 8, 2026
|
Details |
|
Flexible Hystero-Fiberscope Kits REF: 11264BBU1, 11264BBUK1, that contain expired Single Use Endoscopic Seal: GYN, REF: 26153EAU/1.
Flexible hysteroscopes indicated for use during diagnostic and operative hysteroscopic procedures may contain an expired single use endoscopic seal for gynecology use, which could impact the assurance of sterility.
|
FDA
Z-2794-2026
|
Medical Device | High |
Jul 29, 2026
Recall: May 21, 2026
|
Details |
|
Hotline Fluid Warming Set, single use device, is designed to warm blood and intravenous fluids and deliver them to the patient's intravenous access site at normothermic temperatures under gravity flow conditions, List Number L-70
ICU Medical became aware of an increased likelihood of leakage in specific Lots of L-70 HOTLINE Fluid Warming Sets due to potentially inadequate solvent application at the tubing to return connector bond.
|
FDA
Z-2759-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 24, 2026
|
Details |
|
MEDLINE medical procedure convenience kit labeled as: 1) TOTAL KNEE-LF, Medline kit SKU CDSOPT590T; 2) TOTAL KNEE-LF, Medline kit SKU CDSOPT590U; 3) TOTAL KNEE CDS, Medline kit SKU CDS983930J; 4) HIP CDS-LF, Medline kit SKU CDS984556L; 5) HIP CDS-LF, Medline kit SKU CDS984556M; 6) TOTAL KNEE PACK, Medline kit SKU DYNJ905162Q.
The procedure kits contain ICU Medical, Inc. pain management kits containing Bupivacaine Hydrochloride in Dextrose Injection, USP, which were recalled due to quality issues that could result in drug ineffectiveness.
|
FDA
Z-2765-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 8, 2026
|
Details |
|
FARASTAR Ablation Generator EU, Pulsed Field Ablation Generator, Product ID 61M401; Percutaneous Cardiac Ablation Catheter
Labeling discrepancy: Devices distributed with Instructions For Use (IFU) did not include FARAPOINT PFA catheter information.
|
FDA
Z-2750-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 11, 2026
|
Details |
|
MiniMed Go App, Model: MMT-8600 (iOS), MMT-8601 (Android)
For MiniMed Go app version 1.0.0 and 1.1.0, when the Set day and night is turned OFF and missed dose or Correct high glucose alerts are enabled, the associated alerts will not be triggered during the nighttime. This could result in missed rapid-acting insulin doses without the user s knowledge, and may lead to delayed therapy and an increased risk of hyperglycemia.
|
FDA
Z-2778-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 16, 2026
|
Details |
|
SafeOp Patient Interface, REF: AIX11240, part of SafeOp 3: Neural Informatix System
Intraoperative neuromonitoring device, due to a software issue, may experience loss or interruption of triggered electromyography (tEMG) functionality during use, displaying as system faults, loss of communication between the Patient Interface and Tablet, and prompts requiring system reboot; may result in increased operative time and surgical plan change.
|
FDA
Z-2793-2026
|
Medical Device | High |
Jul 29, 2026
Recall: May 13, 2026
|
Details |
|
Penumbra System RED 68 Reperfusion Catheter REF: RED68KIT
Due to manufacturing issues, reperfusion catheters may fractures
|
FDA
Z-2770-2026
|
Medical Device | High |
Jul 29, 2026
Recall: Jun 3, 2026
|
Details |
|
Halyard STANDARD LINE INSERTION PACK. Model/Catalog Number: PVHM234-01. Convenience kit.
Defects in the silicone seal, which may result in "doming" of the silicone seal due to improper sealing, potentially leading to fluid occlusion or leakage.
|
FDA
Z-2772-2026
|
Medical Device | High |
Jul 29, 2026
Recall: May 19, 2026
|
Details |
Review FDA device recalls and early alerts for equipment, software, monitors, implants, diagnostic tools and patient-use devices.
Use the device name, company, product code, UDI, model, catalog number, serial number, lot number, software version or implant card details.
Class I recalls are generally the most serious. Read the FDA notice for patient risk, affected devices, correction/removal steps and clinical action.
If the device supports or monitors health, do not stop treatment based only on a search result. Confirm with the official notice and your clinician when needed.
Use each recall result to compare device name, company, product code, model, serial, lot number, UDI and software version. A similar name is not enough; recalls often apply only to specific versions or production ranges.
Check the notice for FDA recall class, patient risk, correction, removal and clinical action. This helps you decide whether the item should be stopped immediately or handled through a normal remedy process.
Review retailer, online marketplace, state, distribution and purchase-date details when they are available. Some recalls apply only to certain stores or channels.
Use the linked official notice for final instructions such as repair, replacement, refund, disposal, software update, stop-use or company contact.
Search the product name or brand, then compare model, serial, lot, code, date, retailer and official recall number details on the detail page.
Stop using the product if the official notice says to do so, keep the label or packaging, and follow the remedy instructions for repair, refund, replacement or disposal.
Recalls can be limited to certain production dates, factories, lots, model numbers, colors, sizes, retailers or distribution areas.
No. This page helps you search public recall data. Use the linked agency or company notice as the final source before taking action.