| Product Recall | Source | Type | Risk | Date | Action |
|---|---|---|---|---|---|
|
Convenience kits MINOR PACK DYNJ58421A SPRINGHILL MINOR PACK DYNJ40734F
Kits may exhibit open seals in sterile pouch packaging. Open seal may compromise product sterility. If not detected prior to use, issue may lead to contamination of sterile field or patient infection if product is used.
|
FDA
Z-3208-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 31, 2026
|
Details |
|
StatStrip Glucose Hospital Meter System. Model No: 66739. Glucose test system.
A software synchronization/timing issue in the barcode scanning and patient data processing component that causes the device to intermittently retain a previously scanned barcode including patient identification (ID) barcodes and quality control (QC) solution ID barcodes when a new barcode is scanned, resulting in the prior barcode information remaining displayed on the screen for the current test. When this defect occurs and the operator accepts the incorrectly displayed patient information without recognizing the mismatch, the current patient's glucose result will be incorrectly assigned to the previous patient's medical record and transmitted to the data management system (DMS), and the current patient's medical record will not receive a result, leaving their glucose status unrecorded and their clinical management without the information needed to guide treatment decisions. The previous patient, whose medical record now contains a glucose result that does not belong to them, may receive inappropriate clinical intervention based on that erroneous result, particularly in critically ill patients, neonates, and infants who cannot communicate symptoms or self-treat. The defect also affects QC barcode scanning: if a QC scan triggers the same retention behavior, QC results may be attributed to an incorrect identifier or QC tests may fail without the user recognizing the underlying cause. This defect does not affect the analytical accuracy of glucose measurements.
|
FDA
Z-3129-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 29, 2026
|
Details |
|
Enterprise Archive V8, software product for receiving, archiving, and sending electronic medical data, All versions
Under certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be displayed under the wrong patient record, which could lead to misdiagnosis or a delay in patient care.
|
FDA
Z-3167-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 31, 2026
|
Details |
|
Philips Patient Information Center iX REF:866389
Due to software malfunction, patient information system may freeze and become unresponsive.
|
FDA
Z-3141-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 31, 2026
|
Details |
|
REF:B11LT Ethicon Endo-Surgery, Inc. XCEL BLADELESS TROCAR W/STABILITY SLEEVE 11X100MM
Reusable access port system may crack or seperate during use.
|
FDA
Z-3184-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Aug 19, 2026
|
Details |
|
Workflow Core Services V8, intended to provide set of services for storage and retrieval of patient data, exams and performs system Administration, common configuration management for consuming applications, All versions
Under certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be displayed under the wrong patient record, which could lead to misdiagnosis or a delay in patient care.
|
FDA
Z-3170-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 31, 2026
|
Details |
|
SCORPIO RECESSED METAL BACKED PATELLA 3045-0026 3045-0028 3045-0030 3045-0032 Orthopaedic implant components manufactured from UHMWPE (polyethylene)
Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to hazards such as excessive wear debris, material fragments, fractured device, or disassociated device. Potential harms include revision surgery, pain, and inflammation.
|
FDA
Z-3203-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 30, 2026
|
Details |
|
BD Alaris Pump Infusion Sets 10561554* 10885403232565 50885403232563 BD Alaris Pump Infusion Set, 15 Micron Filter, Back Check Valve, 3 SmartSite Y-sites 10015861A 10885403232626 50885403232624 BD Alaris Pump Infusion Set, SmartSite Bag Access Non-Vented, PE Lined Tubing, Back Check Valve, 3 SmartSite Y-sites 11171447* 7613203021234 37613203021242 BD Alaris Pump Infusion Set, 2 Back Check Valves, 3 SmartSite Y-sites 11426965* 10885403232558 50885403232556 BD Alaris Pump Infusion Set, Back Check Valve, 5 SmartSite Y-sites 2260-0500 7613203012591 37613203012608 BD Alaris Pump Infusion Set, PE Li
Due to discrepancies in specific attributes in the performance data for infusion sets, which may lead to inappropriate pump performance.
|
FDA
Z-3080-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Aug 19, 2026
|
Details |
|
SunMed Tracheal Tube, Size 2.5; Model Number: 1-7333-25
The 6Fr suction catheter could not pass through the samples smoothly.
|
FDA
Z-3172-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 31, 2026
|
Details |
|
GM Helix Implant, REF: 109.984;
There is a discrepancy between the product identification on the packaging and the dimensions of the implant contained inside.
|
FDA
Z-3173-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Aug 12, 2026
|
Details |
|
EWO_02512 (Catalog number 320550) For Investigational Use Only Nano Pro Un-Cannulated Demo Samples Quantity 100
Retrospectively reported: Pen needles labeled 'For Investigational Use Only' were inadvertently distributed as commercially marketed devices.
|
FDA
Z-3179-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 26, 2023
|
Details |
|
BEARING AND AXLE BUSHING ASSY STD ELBOW C-M113-1-301 KRH REV TIB INS 16mm THK .640 DIA STEM C-M113-5-600 SELF-PRESSURIZING GLENOID SIZE 9 C-M063-5-800 Orthopaedic implant components manufactured from UHMWPE (polyethylene)
Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to hazards such as excessive wear debris, material fragments, fractured device, or disassociated device. Potential harms include revision surgery, pain, and inflammation.
|
FDA
Z-3202-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 30, 2026
|
Details |
|
StatStrip Glucose and B- Ketone meter. Model No: 66429. Glucose test system.
A software synchronization/timing issue in the barcode scanning and patient data processing component that causes the device to intermittently retain a previously scanned barcode including patient identification (ID) barcodes and quality control (QC) solution ID barcodes when a new barcode is scanned, resulting in the prior barcode information remaining displayed on the screen for the current test. When this defect occurs and the operator accepts the incorrectly displayed patient information without recognizing the mismatch, the current patient's glucose result will be incorrectly assigned to the previous patient's medical record and transmitted to the data management system (DMS), and the current patient's medical record will not receive a result, leaving their glucose status unrecorded and their clinical management without the information needed to guide treatment decisions. The previous patient, whose medical record now contains a glucose result that does not belong to them, may receive inappropriate clinical intervention based on that erroneous result, particularly in critically ill patients, neonates, and infants who cannot communicate symptoms or self-treat. The defect also affects QC barcode scanning: if a QC scan triggers the same retention behavior, QC results may be attributed to an incorrect identifier or QC tests may fail without the user recognizing the underlying cause. This defect does not affect the analytical accuracy of glucose measurements.
|
FDA
Z-3132-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 29, 2026
|
Details |
|
Core Services Hub V8, a set of backend services including Cross Enterprise (XE) and Workflow Core (WFC) services that enables enterprise imaging workflows, All versions
Under certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be displayed under the wrong patient record, which could lead to misdiagnosis or a delay in patient care.
|
FDA
Z-3171-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 31, 2026
|
Details |
|
Halyard IV START KIT NON-STERILE REF: KRIV26-02
Convenience kits contain BD ChloraPrep Clear - 1 mL and FREPP Clear 1.5 mL Applicators which are contaminated with Aspergillus penicillioides
|
FDA
Z-3108-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 14, 2026
|
Details |
|
IV Sets with drip chambers
Intravascular administration tubing set drip chambers may have black specks potentially due to the plastic molding process leaving discolored polyvinyl chloride (PVC) material within the drip chamber wall. The presence of discoloration and particulate matter in the fluid path has not been ruled out.
|
FDA
Z-3163-2026
|
Medical Device | High |
Sep 23, 2026
Recall: May 12, 2026
|
Details |
|
SCORPIO + MOBILE BEARING PCS 78-5-0910 SYSTEM ONE BIPOLAR 40MM 6074-4022 SYSTEM ONE BIPOLAR 43MM 6074-4322 SYSTEM ONE BIPOLAR 44MM 6074-4422 Orthopaedic implant components manufactured from UHMWPE (polyethylene)
Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to hazards such as excessive wear debris, material fragments, fractured device, or disassociated device. Potential harms include revision surgery, pain, and inflammation.
|
FDA
Z-3205-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 30, 2026
|
Details |
|
FDA
Z-2984-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Aug 10, 2026
|
Details | |
|
Medline Convenience Kits: 1) ACC010308A, Catalog Number: ACC010308A; 2) ACC010374A, Catalog Number: ACC010374A; 3) ACC010679, Catalog Number: ACC010679; 4) ACC010726A, Catalog Number: ACC010726A; 5) DYNDB3061, Catalog Number: DYNDB3061; 6) DYNDH1245, Catalog Number: DYNDH1245; 7) DYNDH1362, Catalog Number: DYNDH1362
The kits contain certain lots of sterile applicators which may contain fungal contamination that may occur under certain environmental conditions, allowing the growth of Aspergillus penicillioides. Contamination of skin preparation products with Aspergillus penicillioides may lead to serious adverse health consequences, including systemic infection, sepsis, illness, and death.
|
FDA
Z-3124-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Aug 11, 2026
|
Details |
|
DURACON XL ANGLED TIB INS 11/14MM C-M064-1-300 SELF-PRESSURIZING GLENOID SIZE 8 C-M062-6-800 C-M062-7-500 C-M063-2-600 SELF-PRESSURIZING GLENOID SIZE 9 C-M063-5-000 SHOULDER - GLENOID #11 5361-6111 SHOULDER - GLENOID #5 5361-6105 SHOULDER - GLENOID #7 5361-6107 SHOULDER - GLENOID #9 5361-6109 SHOULDER - KEELED GLENOID #11 5361-6211 SHOULDER - KEELED GLENOID #5 5361-6205 SHOULDER - KEELED GLENOID #7 5361-6207 SHOULDER - KEELED GLENOID #9 5361-6209 Orthopaedic implant components manufactured from UHMWPE (polyethylene)
Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to hazards such as excessive wear debris, material fragments, fractured device, or disassociated device. Potential harms include revision surgery, pain, and inflammation.
|
FDA
Z-3200-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 30, 2026
|
Details |
|
ALL POLY CONSTRAINED INSERT 54MM 69-2854 NRG KNEE CR 82-2-0512 82-2-0518 82-2-0912 NRG KNEE P/S 82-3-0318 SCORPIO + MOBILE BEARING PCS 78-5-0910 SCORPIO C-DOME PATELLA 73-2710 SCORPIO INSET PATELLA 73-2610 SCORPIO M-DOME PATELLA 73-0110 73-0710 73-0910 SCORPIO RECESSED PATELLA 26MM 3044-0026 SCORPIO TS TIB INS 72-4-9114 SCORPIO TS TIBIAL INSERT 72-4-0324 SCORPIOFLEX TOTAL KNEE CR 72-16-0512 72-16-0518 72-16-0912 72-16-1112 SERIES II TIBIAL BEAR INSERT NO 11 15MM 3052-1115 UHR BIPOLAR 26X52mm UH1-52-26 UHR BIPOLAR 26X58mm UH1-58-26 UHR BIPOLAR 28X48mm UH1-48-28 UHR BIPOLAR 28X52mm UH1-52-28 UHR
Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to hazards such as excessive wear debris, material fragments, fractured device, or disassociated device. Potential harms include revision surgery, pain, and inflammation.
|
FDA
Z-3197-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 30, 2026
|
Details |
|
REF:B12LT Ethicon Endo-Surgery, Inc. XCEL BLADELESS TROCAR W/STABILITY SLEEVE 12X100MM
Reusable access port system may crack or seperate during use.
|
FDA
Z-3185-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Aug 19, 2026
|
Details |
|
Happiest Baby, Inc. SNOO Sleep Sack, X-Large Model/Catalog Number: S2101-501 S2101-508-11 S2101-508-3 S2101-508-4 S2101-508-5 S2101-508-6 S2101-508-7 S2101-512 S2101-513 S2101-532 S2101-533 S2101-534 S2101-535 S2101-536 S2101-541 S2101-551 S2102-508-10 S2102-508-9 S2103-501 S2103-502 S2103-504 S2103-508-11 S2103-508-12 S2103-508-13 S2103-508-14 S2103-508-6 S2103-508-7 S2103-508-8
Extra small (ES) and Extra-large (XL) infant sleep sacks have not been reviewed for safety and effectiveness by the FDA.
|
FDA
Z-3176-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Aug 7, 2026
|
Details |
|
Convenience kits ANESTHESIA PAIN PK LEAGUE DYNJ67925A
Kits may exhibit open seals in sterile pouch packaging. Open seal may compromise product sterility. If not detected prior to use, issue may lead to contamination of sterile field or patient infection if product is used.
|
FDA
Z-3207-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Jul 31, 2026
|
Details |
|
Brand Name: VERIQA; Product Name: RT MonteCarlo 3D v3; Model/Catalog Number: S070031.520; Software Version: 3.1.18;
When a bolus is included in a treatment plan and sent for secondary dose calculation, the software accounts for it but does not display this clearly, which may lead users to incorrectly omit the bolus during treatment and deliver the prescribed dose to the wrong tissue depth.
|
FDA
Z-3174-2026
|
Medical Device | High |
Sep 23, 2026
Recall: Aug 4, 2026
|
Details |
Use the Today filter when you want newly published recall alerts from the current U.S. date. If no results appear, check the last 7 or 10 days because agencies may publish updates in batches.
Recent recalls can include new notices, updated classifications, expanded lots, changed risk levels and public health alerts. Sort by newest first for the live recall feed view.
High-risk notices often involve serious injury, contamination, undeclared allergens, vehicle crash hazards, fire risks or products that should not be used or consumed.
This latest recall page combines CPSC, FDA, USDA FSIS and NHTSA data so shoppers do not need to check each agency page separately.
New alerts for toys, furniture, appliances, electronics, baby products, household goods and products with injury, choking, fire or fall hazards.
Recent FDA notices can include Class I, Class II and Class III recalls, market withdrawals, safety alerts, code information and distribution areas.
FSIS alerts cover meat, poultry and egg products, including public health alerts, undeclared allergens, pathogen risks and misbranding issues.
New vehicle, tire, equipment and child-seat campaigns include defect summaries, affected units, remedy notes and NHTSA campaign numbers.
Recent recall pages are date-driven. Use the published date and recall date to understand whether an alert is new, newly classified or recently updated.
Choose food, vehicle, medical device, baby product, electronics, household or consumer product when the latest list is too broad.
Sort by highest risk when checking for urgent problems such as contamination, serious injury hazards, undeclared allergens, fire risks or vehicle safety defects.
Use the detail page and official source link before taking action. Agency notices may include exact lot codes, model ranges, remedy steps and company contacts.
The site syncs official recall sources daily and stores updated records by source agency, dataset and official recall ID.
Some agencies publish or classify a recall after the company began the recall. Use both the published date and recall date when reviewing a notice.
Match the brand, product name, package size, UPC, lot code, best-by date, allergen or contamination issue and distribution area before taking action.
Yes. Use the risk filter or highest-risk sort to surface recalls marked critical or high risk across all official sources.